Establish
0

NOVEC 1230 Gas Suppression System for Critical Spaces

Protect your most valuable assets with our NOVEC 1230 Gas Suppression System, a next-generation, environment-friendly fire suppression system that extinguishes fires within seconds, leaves zero residue, and keeps your people and equipment completely safe.
0 M
Ready to protect
across various industries

What Happens When You Ignore Fire Safety in Critical Zones

A single fire incident in a sensitive facility can wipe out years of data, assets, and business continuity in minutes.

Equipment Loss

Servers, switches, and control panels destroyed by fire or water cannot be recovered. Downtime costs can reach lakhs within hours.

Data Collapse

Unprotected data centers face irreversible data loss. Without a clean agent gas fire protection system, backup recovery becomes impossible.

Legal Liability

Non-compliant fire safety setups expose your business to regulatory penalties, insurance denial, and legal action post-incident.

Business Shutdown

Fire violations trigger immediate shutdowns. Businesses lacking proper fire safety products and hydrant systems risk overnight closure.

How a Clean Agent Fire Suppression System Operates

From early smoke detection to agent discharge in under 10 seconds our systems stop fires before they can cause serious damage.

Early Fire Detection

Smoke, heat and flame sensors detect fire at the earliest stage triggering instant alerts before flames spread across zones.

Instant Alert System

Once a threat is detected, the control panel activates audible and visual alarms alerting every occupant to evacuate safely.

Active Suppression

Suppression systems sprinklers, hydrants, extinguishers or gas agents control and extinguish fire before it can spread.

Regular AMC & Upkeep

Regular AMC and preventive maintenance keeps every fire protection system tested, calibrated and NBC compliant at all times.

Fire Suppression System Types We Design & Install

Every facility has a unique fire risk. We offer a full range of engineered fire protection solutions tailored to your environment.

Clean Agent

The NOVEC 1230 Gas Suppression System uses a fluoroketone agent that is colorless, odorless, and electrically non-conductive for total flooding.

Inert Gas

Argon and nitrogen-based systems reduce oxygen levels to suppress fire in large enclosed spaces without affecting sensitive equipment.

CO2 Systems

High-concentration carbon dioxide suppression is ideal for unmanned industrial zones, generator rooms, and electrical cable vaults.

FM-200

A widely used HFC-based clean agent alternative, though now being replaced by the more eco-friendly Novec 1230 clean agent fire suppression solution.

Water Mist

Ultra-fine water droplets suppress fire and cool surfaces simultaneously suitable for areas where chemical agents are not preferred.

Tube-Based

Self-actuating detection tubes installed inside server racks and UPS panels for localized, automatic, and power-free fire suppression.

Choose the Right Fire Protection System for Your Business

Not every building needs the same system. We help you choose the right NBC-compliant fire protection solution for your property.

01

Fire Sprinkler Systems

Heat-activated sprinklers control fire instantly NBC & IS:15105 compliant for malls, offices and residential buildings.

Gas Suppression Systems

FM200, Novec 1230 & CO2 extinguisher systems protect server rooms and electrical panels clean, residue-free, no damage.

02

03

Foam Systems

Foam systems smother flammable liquid fires in fuel tanks and petrochemical plants ideal for high-risk industrial sites.

Fire Detection Systems

Smoke, heat & flame detectors with IS:2189 compliant panels alert occupants instantly mandatory for NBC-compliant buildings.

04

Where We Deploy NOVEC 1230 Gas Suppression Systems

Our data center fire suppression Novec 1230 solutions are trusted across industries where equipment continuity and asset safety are critical.

High-Rise Buildings

Mandatory for buildings above 15m under NBC our certified fire safety systems protect every floor, stairwell and common space.

Hospitals & Healthcare

Hospitals store oxygen and flammables. Our certified fire safety systems protect patients and critical medical equipment 24/7.

IT Parks & Data Centres

IT parks house costly servers and our fire safety systems deliver fast, reliable zone-level protection with minimal disruption.

Factories & Warehouses

Factories hold bulk flammable stock. Our systems protect every indoor zone and the full outer perimeter of your facility.

Malls & Commercial Hubs

Malls host thousands daily and our fire safety systems ensure complete NBC-compliant protection across every zone and floor.

Petrochemical Plants

Oil refineries face extreme fire risk. Our systems with foam suppression are NBC-mandatory for all compliant industrial plants.

Precision Engineering Behind Every Suppression System

Our engineering team follows NFPA 2001 and ISO 14520 standards to design every NOVEC 1230 Gas Suppression System from ground up. From hazard classification and hydraulic calculations to nozzle placement and enclosure integrity every detail is engineered for maximum protection.

Hazard Survey

We assess fuel loads, ignition risks, room dimensions, airflow patterns, and enclosure characteristics before initiating system design.

Agent Quantity

Using hydraulic calculation software, we determine the exact volume of Novec 1230 clean agent fire suppression fluid required per zone.

Nozzle Layout

360° or 180° discharge nozzles are positioned to ensure uniform agent distribution across the entire protected area within 10 seconds.

Cylinder Sizing

High-strength steel cylinders super-pressurized with nitrogen at 25 or 42 bar are selected based on system volume and discharge rate.

Detector Zoning

Photoelectric smoke detectors are zoned with cross-zoning logic to eliminate false triggers while ensuring rapid incipient fire detection.

Enclosure Check

We evaluate door seals, HVAC dampers, cable penetrations, and structural integrity to maintain agent concentration for the required hold time.

From Installation to Full System Integration Seamlessly

Our certified technicians install every automatic gas-based fire suppression system with zero disruption to your live operations or uptime.

01

Audit

We start with a certified fire safety audit assessing fire risks, NBC compliance gaps and Fire Hydrant System requirements.

02

Design

Our engineers prepare IS:3844 & NBC-compliant blueprints covering hydrant layout, pipe routing and pump house design.

03

Engineering

Our certified engineers handle hydraulic calculations, pump selection and Fire Hydrant System engineering as per NBC norms.

04

Supply

We supply IS-certified pipes, valves, hydrant boxes and ABC extinguisher supply from trusted fire safety products suppliers.

05

Installation

Our technicians install Fire Hydrant Systems precisely covering piping, pump house, hydrant points and system integration.

Rigorous Testing & Commissioning for Every System

Every NOVEC 1230 Gas Suppression System we install undergoes mandatory Room Integrity Testing as per ISO 14520 and NFPA 2001. We verify agent hold time, enclosure pressure, detector response, alarm sequencing, and discharge timing ensuring your system performs flawlessly when it matters most.

Hydrostatic Testing

All pipelines are hydrostatic tested at 1.5x working pressure detecting leaks and pipe failures before your system goes live.

Flow & Pump Testing

We verify fire pumps and standby diesel pumps auto-activate and maintain required pressure at every Fire Hydrant System point.

Safety & NOC Checks

Our checks cover valve operation, hose reels, water quality, ABC extinguisher supply and safety signage as per NBC 2016.

Fire NOC & Handover

After commissioning, we deliver Fire NOC documents, test reports and AMC support keeping your building legally compliant.

Add Your Heading Text Here

Compliance, Standards & Certifications We Follow

Every fire safety system we install is fully certified, legally compliant and approved built to national and international standards.

Add Your Heading Text Here

Add Your Heading Text Here

Add Your Heading Text Here

Add Your Heading Text Here

Explore Our Fire Hydrant System Services

New India Fire Tech offers end-to-end Fire Hydrant System services from design and installation to accessories supply, AMC and Fire NOC support. As fire safety products suppliers, we deliver NBC-compliant solutions for every building type.

System Installation

Complete hydrant system installation site survey, NBC-compliant design, pipe laying, pump setup and full commissioning.

Pump Room Design

Pump rooms with electric, diesel and jockey pumps ensuring consistent and reliable pressure across your hydrant network.

Accessories Supply

IS-certified hydrant accessories valves, hose reels, nozzles and hose boxes from a trusted extinguisher supplier near you.

AMC & Maintenance

Our AMC covers monthly pump checks, quarterly flow tests and annual audits keeping your system Fire NOC ready.

Fire NOC Assistance

We handle all Fire NOC documentation test reports, drawings and compliance records for fast fire department approval.

Fire Safety Insights, Tips & Industry Updates

Explore expert insights, safety tips, and the latest updates from a fire safety and solutions provider to help you stay informed, compliant, and protected.

New India Fire Tech

Real feedback from clients who trust our fire safety solutions.

4.5k+

What Our Clients Say About Our Fire Safety Services

Industries, corporates, and institutions share their real experience with New India Fire Tech’s trusted fire safety services.

Join Our Trusted Fire Safety Clients Today

Hundreds of businesses trust us for certified fire safety. Let us protect your premises with the same proven expertise and reliability.

FAQs About NOVEC 1230 Gas Suppression System

Yes. With a NOAEL of 10% and a design concentration of just 4.2–6%, it is fully safe for human-occupied facilities.
No. It evaporates completely after discharge, leaving zero residue so your equipment can resume operation almost immediately.
The system detects fire at its incipient stage and discharges the agent within 6–10 seconds of detection.
Absolutely. It has zero ozone depletion potential, a GWP of 1, and an atmospheric lifetime of just 5 days making it the most sustainable clean agent available.
Yes. Unlike FM-200 which is being phased out, the NOVEC 1230 Gas Suppression System is fully compliant with current and future regulations under NFPA 2001 and ISO 14520.